Influência do pré-aquecimento de um sistema adesivo convencional de três passos e de um cimento resinoso fotoativado na resistência de união à dentina
Daniel Brandão Vilela Holanda.
Dissertação
por
D2
2012.
85 f.
Dissertação (Mestrado em Clínica Odontológica) - Centro de Pesquisas Odontológicas São Leopoldo Mandic, Campinas - SP.
O objetivo deste estudo foi avaliar a influenciado aquecimento do adesivo (bond) de um sistema adesivo convencional de três passos (Scotchbond Multipurpose Adhesive/ 3M ESPE) e do cimento resinoso fotoativado (Relyx Venner/ 3M ESPE) na resistência de união à dentina e o modo de fratura. As...
Ver mais
O objetivo deste estudo foi avaliar a influenciado aquecimento do adesivo (bond) de um sistema adesivo convencional de três passos (Scotchbond Multipurpose Adhesive/ 3M ESPE) e do cimento resinoso fotoativado (Relyx Venner/ 3M ESPE) na resistência de união à dentina e o modo de fratura. As superfícies oclusais de 40 terceiros molares humanos foram removidas, expondo uma superfície de dentina que foi planificada. Os dentes foram aleatoriamente distribuídos entre quatro grupos para receber a cimentação de blocos de resina indireta (SR Adoro/ Ivoclar Vivadent) (n=10): G1- bond do sistema adesivo convencional de três passos e cimento resinoso, ambos à temperatura ambiente; G2- bond do sistema adesivo convencional de três passos com pré-aquecimento a 580C do adesivo e cimento resinoso à temperatura ambiente; G3- bond do sistema adesivo convencional de três passos à temperatura ambiente e cimento resinoso pré-aquecido a 580C; G4- bond do sistema adesivo convencional de três passos com pré-aquecimento a 580C da do adesivo e cimento resinoso pré-aquecido a 580C. O conjunto dente/bloco foi preparado para obtenção de corpos-de-prova na forma de palitos de aproximadamente 1mm2 que foram utilizados no teste de microtração. Os corpos de prova foram tracionados em máquina de ensaios universal (Emic) com velocidade de 0,5mm/min. Após a fratura, todos os palitos foram observados em estereomicroscópio com aumento de 40 vezes e classificados em fratura adesiva, mista e coesiva. A análise de variância foi aplicada em esquema fatorial 2x2 (adesivo x cimento), considerando o nível de significância de 5%. Não houve diferença significativa entre os grupos com e sem bond aquecido (p=0,8411), nem entre com e sem cimento aquecido (p=0,7155). A interação bond x cimento não foi significativa (p=0,9389). Não houve diferença estatisticamente significante quanto ao tipo de fratura em relação ao pré-aquecimento realizado. A utilização do pré-aquecimento do adesivo (bond) do sistema adesivo convencional e/ou do cimento resinoso fotoativado utilizados para cimentação não influenciou na resistência de união à dentina e no modo de fratura.
Palavras-chave: Pré-aquecimento. Cimento resinoso. Microtração. Sistema adesivo.
The aim of this study was to evaluate the influence of heating the conventional three-step adhesive bond system (Scotchbond Multipurpose Adhesive/ 3M ESPE) and light activated resin cement (Relyx Venner/ 3M ESPE) on bond strength to dentin and the fracture mode. The occlusal surfaces of 40 human third molars were removed to expose a dentin surface that was flattened. The teeth were randomly distributed into four groups to receive the cementation of indirect resin blocks (SR Adoro/ Ivoclar Vivadent) (n=10): G1- conventional 3-step adhesive bond system and resin cement, both at room temperature; G2-conventional 3-step adhesive bond system, with the bond pre-heated to 580C and resin cement at room temperature; G3-conventional 3-step adhesive bond system at room temperature and the resin cement preheated to 580C; G4-conventional 3-step adhesive bond system with pre-heating of the bond to 580C and resin cement preheated to 580C. The tooth/block set was prepared to obtain sticks test specimens measuring approximately 1mm2, which were used in the microtensile test. The test specimens were subjected to microtensile testing in a universal test machine (Emic) at a speed of 0.5mm/min. After fracture, all the sticks were observed under a stereomicroscope at 40X magnification and fractures were classified as adhesive, mixed and cohesive types. Factorial analysis of variance was applied, 2x2 (bond x cement), considering the level of significance of 5%. There was no significant difference among the groups with and without bond heating (p=0.8411), or among those with and without heated cement (p=0.7155). The interaction bond x cement was not significant (p<0.9389). There was no statistically significant difference of the fracture mode according to the preheating treatment. The use of preheating of the bond of the conventional adhesive system and/or of the light activated resin cement used for cementation did not influence the bond to and the fracture mode of dentin.
Keywords: Preheating. Resin Cement. Microtensile. Adhesive System. Ver menos
Palavras-chave: Pré-aquecimento. Cimento resinoso. Microtração. Sistema adesivo.
The aim of this study was to evaluate the influence of heating the conventional three-step adhesive bond system (Scotchbond Multipurpose Adhesive/ 3M ESPE) and light activated resin cement (Relyx Venner/ 3M ESPE) on bond strength to dentin and the fracture mode. The occlusal surfaces of 40 human third molars were removed to expose a dentin surface that was flattened. The teeth were randomly distributed into four groups to receive the cementation of indirect resin blocks (SR Adoro/ Ivoclar Vivadent) (n=10): G1- conventional 3-step adhesive bond system and resin cement, both at room temperature; G2-conventional 3-step adhesive bond system, with the bond pre-heated to 580C and resin cement at room temperature; G3-conventional 3-step adhesive bond system at room temperature and the resin cement preheated to 580C; G4-conventional 3-step adhesive bond system with pre-heating of the bond to 580C and resin cement preheated to 580C. The tooth/block set was prepared to obtain sticks test specimens measuring approximately 1mm2, which were used in the microtensile test. The test specimens were subjected to microtensile testing in a universal test machine (Emic) at a speed of 0.5mm/min. After fracture, all the sticks were observed under a stereomicroscope at 40X magnification and fractures were classified as adhesive, mixed and cohesive types. Factorial analysis of variance was applied, 2x2 (bond x cement), considering the level of significance of 5%. There was no significant difference among the groups with and without bond heating (p=0.8411), or among those with and without heated cement (p=0.7155). The interaction bond x cement was not significant (p<0.9389). There was no statistically significant difference of the fracture mode according to the preheating treatment. The use of preheating of the bond of the conventional adhesive system and/or of the light activated resin cement used for cementation did not influence the bond to and the fracture mode of dentin.
Keywords: Preheating. Resin Cement. Microtensile. Adhesive System. Ver menos
Influência do pré-aquecimento de um sistema adesivo convencional de três passos e de um cimento resinoso fotoativado na resistência de união à dentina
Daniel Brandão Vilela Holanda.
Influência do pré-aquecimento de um sistema adesivo convencional de três passos e de um cimento resinoso fotoativado na resistência de união à dentina
Daniel Brandão Vilela Holanda.
Exemplares
Nº de exemplares: 1
Não existem reservas para esta obra